pewag
This table provides information on how to get the best use from the pewag lashing systems. This table also shows you the maximum load which can be secured with 1 lashing system given the angles and dynamic friction factors referred to. Please note that when friction lashing min. 2 lashing systems are needed. Additional securing methods (i.e. wedges, or similar) have not been taken into account. These could be used to secure loads with even higher weights. Please contact our customer service. The values in the table are applicable in the event that the same tension force (STF) is not effective in the lashing system on both sides of the load due to the deflection and edges. If this can be determined (e.g. using a pretensioning gauge), the values in the table may be increased by a factor of 1.3. The maximum loading weight depends on the STF value of the tensioning system – the value is shown on the lashing system‘s tag. Every lashing system has its own table. The maximum forces occurring due to acceleration, braking and avoidance maneuvers in road traffic acc. EN 12195-1 were taken into account. Other tables are applicable for transport by rail and sea. Please contact our customer service.
  • Grade: 10
Frictional lashing of loads on trucks_1
Currently this product cannot be added to an online quote. Please contact us directly for enquires.

 

ZRSW 7 with RSW 7/8 Loadbinder STF 1900 (daN)

Angle to surface
Max. load at dynamic friction factor
 
 
 
 
 
α
0,1
0,2
0,3
0,4
0,5
0,6
90º
400
950
1.710
2.850
4.750
8.550
85º
400
940
1.700
2.830
4.730
8.510
80º
400
930
1.680
2.800
4.670
8.420
70º
380
890
1.600
2.670
4.460
8.030
60º
350
820
1.480
2.460
4.110
7.400
50º
310
720
1.300
2.180
3.630
6.540
40º
260
610
1.090
1.830
3.050
5.490
30º
200
470
850
1.420
2.370
4.270

 

ZRSW 8 with RSW 7/8 Loadbinder STF 1900 (daN) 

Angle to surface
Max. load at dynamic friction factor
 
 
 
 
 
α
0,1
0,2
0,3
0,4
0,5
0,6
90º
400
950
1.710
2.850
4.750
8.550
85º
400
940

1.700

2.830
4.730
8.510
80º
400
930
1.680
2.800
4.670
8.420
70º
380
890
1.600
2.670
4.460
8.030
60º
350
820
1.480
2.460
4.110
7.400
50º
310
720
1.300
2.180
3.630
6.540
40º
260
610
1.090
1.830
3.050
5.490
30º
200
470
850
1.420
2.370
4.270

 

ZRSW 10 with RSW 10 Loadbinder STF 3000 (daN)

Angle to surface
Max. load at dynamic friction factor
 
 
 
 
 
α
0,1
0,2
0,3
0,4
0,5
0,6
90º
640
1.500
2.700
4.500
7.500
13.500
85º
640
1.490
2.680
4.480
7.470
13.440
80º
630
1.470
2.650
4.430
7.380
13.290
70º
600
1.400
2.530
4.220
7.040
12.680
60º
550
1.290
2.330
3.890
6.490
11.690
50º
490
1.140
2.060
3.440
5.740
10.340
40º
410
960
1.730
2.890
4.820
8.670
30º
320
750
1.350
2.250
3.750
6.750

 

ZRSW 13 with RSW 13 Loadbinder STF 2500 (daN)

Angle to surface
Max. load at dynamic friction factor
 
 
 
 
 
α
0,1
0,2
0,3
0,4
0,5
0,6
90º
530
1.250
2.250
3.750
6.250
11.250
85º
530
1.240
2.240
3.730
6.220
11.200
80º
520
1.230
2.210
3.690
6.150
11.070
70º
500
1.170
2.110
3.520
5.870
10.570
60º
460
1.080
1.940
3.240
5.410
9.740
50º
410
950
1.720
2.870
4.780
8.610
40º
340
800
1.440
2.410
4.010
7.230
30º
260
620
1.120
1.870
3.120
5.620

Download CAD

Description

Get CAD
Download